Land Development and Planning Project Files_3400 S. Ocean Blvd._20190702_Application No. 19-0138TRANSMITTAL FORM REPORT OF REVIEW & ACTION BY TOWN COMMISSION Transmit to: Building Official Massie Building Department Date: July 10, 2019 Applicant/Owner: Coronado at Highland Beach Condo Association, Inc. Property Address: 3400 South Ocean Boulevard, Highland Beach, FL 33487 Property Control Number: 24-43-46-33-24-000-0311 REVIEW GIVEN TO SUBJECT PROPETY D Preliminary Review: � Final Review: Replace/Repair Failing Seawall along the Intracoastal Waterway D Amended Site Plan Review D Other: AT THE JULY 2, 2019, REGULAR MEETING, TOWN COMMISSION REVIEWED THE ABOVE MATTER PER THE REQUEST OF THE BUILDING OFFICIAL DATED MARCH 11, 2019, AND HEREBY CERTIFIES THAT THE FOLLOWING ACTION WAS TAKEN: D Denied � Recommendation to Approve (Coronado Condominium Bulkhead Replacement Plans dated June 5, 2019) D Approved with Modifications ( as noted) D Other: PLEASE TAKE WHATEVER ACTION IS REQUIRED TO COMPLETE THE SUBJECT MATTER, i.e., ISSUE PERMIT, TRANSMIT TO TOWN COMMISSION, RETURN TO APPLICANT, ETC. ()J, J�Rlioda Zelniker, IF THE ABOVE PLANS WERE DENIED OR APPROVED WITH MODIFICATIONS, PLEASE NOTE THE BOARD'S FINDINGS: [MOTION: Vice Mayor Babij moved to approve Application 19-0370. Commissioner David seconded the motion. UPON ROLL CALL: Vice Mayor Babij - Yes; Commissioner David - Yes; Commissioner Gossett-Seidman - Yes; and Mayor Zelniker - Yes. Motion carried on a 4-0 vote. APPROVED by Town Commission 7/2/2019 Application 19-0138 APPROVED by Town Commission 7/2/2019 HIGHLAND BEACH BUILDING DEPARTMENT DATE: July 2, 2019 3614 S. Ocean Boulevard Highland Beach, FL 33487 Ph: (561) 637-2003 TO: Town Commission MEETING OF: July 2, 2019 TOWN COMMISSION STAFF REPORT SUBJECT: CORONADO SEAWALL REPLACEMENT (APPLICATION# 19-0370) FROM: Jeffrey Massie, Building Official Applicant Coronado at Highland Beach Condo Association, Inc Property Owner Name: Address: Property Characteristics Zoning District: Site Location: Parcel PCN#: Request Coronado at Highland Beach Condo Association, Inc 3400 S. Ocean Blvd 3K Highland Beach, FL 33487 RMM, Residential Multiple Family Medium Density 3400 S. Ocean Blvd 24-43-46-33-24-000-0311 The applicant is proposing to replace/repair failing seawall along the lntracoastal Waterway. AGENDA ITEM 12B TOWN COMMISSION 3400 S. Ocean Blvd June 10, 2019 Application # Pending Page 2 of 4 ~ . . II. ZONING AND LA~D USE: The lot is located on the lntracoastal side of Al A. The area of the lot is approximately 13,486 square feet. The table below lists the zoning district and existing land use for the subject site and surrounding area. Subject Site RMM, Residential Multiple Family Medium Density Multiple Family North RMH, Residential Multiple Family Hi h Density Multiple Family South RMM & GSD, Residential Multiple Family Medium Density & Government Service District Multiple Family & Open Space Recreational East RMM & RMH, Residential Multiple Family Medium Density & Residential Multiple Family Hi h Density Multiple Family West Water Water Existing Condition The seawall in place has reached/exceeded its expected service life and in the opinion of Jason Taylor, PE (Cummins Cederberg Inc.) is in "Serious" condition overall. From Mr. Taylor's report of January 2018, "We recommend replacement within the next 2 years. . .. failure of the seawall may be sudden." TOWN COMMISSION 3400 S. Ocean Blvd June 10, 2019 Application # Pending Page 3 of 4 Proposed Changes The applicant is proposing install approximately 443 feet of steel sheet piles, 42 prestressed concrete batter piles, new cast in place concrete seawall cap, and partial removal/repair of 9 wood finger docks. Development Standards • Seawall construction requires approval by Town Commission (Sec 6-127 (a)); • Building permits required (Sec 30-42); • Notification requirements within 1000 feet abutting proposed construction (Sec 6-128 (a)); • Seawalls west of A 1 A shall have elevations in excess of 6 feet above sea level (6.00 feet NGVD or 4.5 feet NAVO) (Sec 6-128 (b)). 1 t' ~ ,.,. ~ ~:, -i .-\ • • ~ • -,<, ' '\. •, • , < '~ ' ' \ I IV. RECOMMENDATIONS: The Town of Highland Beach Building Department has reviewed the building plans submitted by the applicant and has found that the proposed construction does comply with the Florida Building Code and the Highland Beach Code of Ordinances. V. OTHER MATTERS: The Building Official has reviewed the application and submitted documents on June 10, 2019, and hereby certifies the following action was taken: TOWN COMMISSION 3400 S. Ocean Blvd June 10, 2019 Application # Pending Page 4 of 4 ~ Plans meet Town of Highland Beach Zoning and other governmental agencies requirements. D Plans meet Town of Highland Beach Zoning requirements; however, approvals are pending before the Town of Highland Beach will issue permits, with other governmental agencies as listed: D Plans do not meet Town of Highland Beach Zoning requirements. Should you have any further questions with regards to the matter please feel free to contact me at (561) 637-2003 or jm ass ie@ hig hl a n dbeach .u s Respectfully Submitted, Jeffrey Massie, CFM Building Official Town of Highland Beach L _:B::..::U:.:.:l L=D~I N~G:......:0:::-=E::.....P . .__A R_T_M_E N_T__. Application # . I request a.hearing regarding the terms of the Zonini Ordinances of the Town of Highland Beach. This request relates to the propeiy and zoning requirements set forth 1 • s · J lie · !fiG> 1 • • ':!1-~~~:i~~:~J~i4-0--4.t~r·a;4(.:,4frf:( ,-:,-·t::'.-'·--·::" ·>':·:'··· ·,.···,· .:_ .: :: ,·i ·:::··,r~·: .. -:--:.:· ·::-·:'··:··; ·:·-,·_,., ~-~··,·.-. --.· :~ . ~ 3~--:. .. :! , ... --. -~ -. ... ,-{){(/_: . i 0 ! . . :· Full Legal DescriJ>tion of the Prop~rty [as described in the deed] or reference to an attachment: . 6,,;ndd, ffe y,{/a,zcl,, ,&ac,4__, t'P-1~@:1 .. /-l1m. / ,th L-. . . .. Zoning District: W4at is the location of the installation? rn'1il.tracoastal Waterway (ICW) q Interior Canal/Basin o N/A Name:i/~~a/-6~~d'8r??Ch (b;-1Nr; I Phone: S6l-Z7cf-ll?J(J I.Fax:$/--· 2-7?-bl ra fylalling Address: ._?w"u / vcea/l, /,3/t;,~( llttL/d/l?[ (3eac~, FL 33'~<? 7 /{/ , JWl{RJ:1'.@.iN:XtlNETI~tlUij'sz;~ Na~e: / M~ a/ a6.t1rL. Mailing Address: Phone: Fax: Email Address: Nam_e: Ul/'A#U/.ttf (l?d'e?/(J-tJ'j-,,; I Phone: ~t"l-2J0-9:l30 I Fax~ 3~S"'-97Cf-/767 Mailing Address: 5"0 ._( aJ. /1-t#i/ /, u!Jtl /e 3t>ef; )ULlifer; H-, 33 Lf 77 V __. v Provide a brief description of the project: t~/tlfAlz;,_cl. /t(Pi:-~e ., ~ /L ??4-A~" JJlr4t.~arz!z:?-t /ia-frn'.,(~,1. ?/ a/ u1!:::7/t/.t2/.l I~ . (7' a-/ ~~ r:;'1r« d~ #-J . irtJJC/u!L )1~ · r I J RECEIVED Revised 1/2019 JUN 1 0 2019 Town of Highland Beach, FL I give permission to the members of the Town Commission, Planning Board and staff to inspeQt the prop_erty for the purpose of thj.s application. I declare that all stat~ments made herein are true, based. upon the best available information . Willful fal~\ state~ents ~a? j.eopardize the validity of ~y applicati?n ~r any de~ision issued t~ereo1;-. I have fully read th~ 1\ 01 at10n outhmng the Board procedures and application requirements . With this application, I am submitt o-ar.y-s..upporting materials listed. Date: /jjf//f 7 I · . -·. .,\ .. · ·-: . , .... \ : : ... ... : · . ~ .. ·-·.····· .-., .. ,,,. . .;,-,~-~---:· ... ~ .. -~.,,.. ....... _.~···· ····· ----~··· · . .:.. ···.:.: -.. ,,t .,,,,_ .. _ .... _, .... ,_ .. -· -··'"''·•·:·· -····-· ................ _ ......... , .. ,._-:.-"···'··-. ····.--·~---· ·· -· . ---..:.-:--····~·. • · Building Department Use: Date Application Received: {.p -I -I q '/);ans meet Town of Highland Beach Zoning and other governmental agencies requirements. D Pla~s nieet Town of Highland Beach Zoning requirements, however, approvals are p ending with other governmental agencies requirements. By: -k,,!\--A,..A....A..6<~__.::=_\-=~~,.L--=:..__:_.,'c:>'" Date: 0_ /J_ 0 Ii_ C/ I I Revise d 1/2 019 RMIT JUN O 7 2019 CORONADO CONDOMINIUM HIGHLAND BEACH I} ~-i 7 BUILDING DEPARTMENT BULKHEAD REPLACEMENT 3400 SOUTH OCEAN BOULEVARD HIGHLAND BEACH, FL 33487 <:: "( UJ t) 0 (.) GULF OF j::: MEXICO <:: "( -.I I- PROJECT "( LOCATION \. \ SHEET INDEX Sheet Sheet Title Number S-1 .0 COVER S-1.1 GENERAL NOTES S-1.2 EXISTING CONDITIONS PLAN S-1.3 SOlL BORINGS S-2.0 DEMOLITION PLAN S-3.0 PROPOSED PLAN VIEW S-3.1 SECTIONS S-3.2 DETAILS PROJECT LOCATION n 1.\1.\11 :\\ 1 (T l >1-1u fr 1z c ( • ... 1,t.11 ., \ I 11111, I ll!_'.111\' I Ill!_'. 7550 RED ROAD, SUITE 217 SOUTH MIAMI, FLORIDA 33143 TEL: +1 305-741-6155 FAX: 305-974-1969 WWW.CUMMINSCEDERBERG.COM www.callsunshine.com lt'sfast.lt'sfree.lt'sthelaw. SHALL BE RtNS£0 WITH FRESH WATER. THE CONCRETE SHA1.L BE Pl/CED IN THE FORMS AND T.AMPED IN Pt.ACE SO THAT AU. HONEYCOMBS WILL BE ELIMINATED AND SUmctENT MORTAR BROUGHT TO A SMOOTH EVEN ANISH BY 1. GENERAL MEANS Of A FLOAT. 1.1. 1HE WORK CONSISTS Of PROW>INC ALL CONSTRUCTION. LABOR. EQUIPMENT. MATERW.. AND OPERATIONS IN 6.3 . CONTRACTOR SH.ILL BE PREPARED TO P!ACE CONCRETE OF LOWER MEMBERS OF THE MARINE STRUCTURES IN CONNECTION WITH THE REPAIR Of THE SEAWAil ANO REIATED INPROIIOIENTS >S SHOWN ON THESE DRAWINGS. SUBIIERGED CONOmONS UTIUZING TREMIE METHODS AT NO AllOtT10IW. COST. Of lHE EIIGINEER. CONSlRUCTION SIWl. NOT CONTINUE UNTll. lHE ENGINEER HAS AOORESSED THE DISCREPANCIES. 1.2. mi DISCREPANCIES IN THE PLHlS WITH THE F1ElO CONDmONS SHAU. BE BROUGHT TO THE IMMEDIATE ATTENTION M . NO CONCRETE SHALL BE POURED DURING UNFAI/ORABLE WfATHER OR SfA CONDITIONS. 6.5. ALL STEEL SHALL HAVE A MINIMUM OF 3 INCHES CONCREI£ CO'l£R, UNL£SS OTHERWISE NOTED. NO CHAIRS OR 'IICtllTY. Nf'I DAMAGE TO PRIVATE OR PUBUC PROPERTY WllHN THE PROJECT 1/!CffiY. INCUJOING STAGlNC SITES. 1.3. THE CONTRACTOR SHAl.l TAKE ALL NECESSARY PRECNJTIONS TO PROTECT EXISTING SIRUCTURES IN 1liE PROJECT OTHER METAL SHALL PROTRUOE: FROM SURfACE OF CONCRETE. WORK AND ACCESS AAfX:, SHA1.L BE REPAIRED PROIIPTI.Y BY THE CONTRACTOR. ANY ~ AS A RESULT Of 6.6. CAST-IN-PIACE CONCRETE SHALL BE A MJNtMUII OF 5,000 PSI COMPRESSIVE STRENGTH AT 28 1-'YS. WATER CEMENT RATIO (W/C) SHALL BE LESS THAN OR EOUN.. TO 0.4. PRO'l1DE MIX DESIGN FOR A CLASS rv CONCRETE THE CONTRACTOR'S Ol'ERATlONS SHAl.l BE REPAIRED AT NO COST TO THE OWNER. AlL >CCESS ANO STAGING FOR AN EXTREMELY AGGRESSIVE (MARINE) EIMRONIIENT IN ACCORIJNlCE WITH FOOT SPEClflCATIONS. PROWlE RESTORED TO THE PRE-CONSTRUCTION CONOmON UPON PROJECT COIIPl£110N AT THE COST OF THE CONTRACTOR. AREAS SHAll BE KEPT NEAT, ORDERLY ANO IN A SAFE MNlNER. AU. J.CCESS ANO STACINC Nlf)S SHALL BE SUFFICIENT AMOUNT OF FLY >SH ANO SIUCA FUME TO THE CEMENT CONTENT. CONTRACTOR SH.Ill. PROVIDE ll!X THE SITE SHAU. BE RESTORED BY REMCMNG ANO F1NISHING AlL EVIO£NCE FOR CONSTRUCTION. IN THE EVENT DESIGN TO ENGINEER FOR APPR<:NAL 10 OAYS PRIOR TO CONCRETE PLACEMENT. INfRASTRUCTURE (SUCH AS WNJ<WAYS, SIOEWAU<S, FENCES, VEGETATION, ETC.) IS TEMPORAlllt.Y REM<MD OR 6.7. NO WATER SHALL BE ADDED TO CONCRETE AT THE JOB SITE UNLESS AUTHORIZED BY THE ENGINEER OR SPECIAL INSPECTOR. RELOCATED OR THERE IS UNAUTHORIZED IWo!AGE TO VEGETATION N>IO/OR FJ.Ctl..lllES B'I' TllE CONTRACTOR, THE 6.8. WHEN SURFACE FINISHING IS COMPLETED. TH£ STRUClURE SHALL BE PROTECTED AGAINST WAVE SPlASH FOR TWO CONlRACTOR SHALL RESTORE AU. OAIIAGE TO STRUCTIJRES AND NATURAL FrAlURES TO PRE--coNSTRUCTlON DAYS AND CURED PER APPUCABL£ PARAGRAPHS OF SECT10N 400-16 OF THE fDOT STANOARO SPECIFICATIONS. CONDITlONS OR BETTER. CURING SHALL OCCUR FOR AT LEAST 7 DAYS. 1.4. UTILITIES ARE NOT SHO'lrW IN THE P\ANS. CONTRACTOR IS RESPONSIBLE FOR LOCATING ALL PRESENT UTIUTlES 6.9. A SURFACE PENETRANT SEALER Of ALKYL-ALKOXY Sl~E CLASSIFICATION, SUCH AS BASF EIMROSEAL, OR PRIOR TO CONSTRUCTION. APPRO\IEO EQUAL SHALl BE APPLIED All. EXPOSED CONCRffi. 1.5. CONTRACTOR IS RESPONSIBLE FOR PRCNIOING PROPER CLE:ARANCE AND PROTECTION TO AU. OVERHEAD WIRES ANO 6.10. APPLY SIKA ARMATEC 110 BONDING AGENT, OR APPROVED EQUAL, AT CONSTRUCTION JOINTS PRIOR TO PLACEMENT OBSTRUCTIONS. OF NEW CONCRffi. 1.6. THE CONTRJ.CTOR SH.Ill. EXCLUDE THE PUBLIC FROM THE WORK AREAS IN THE IMMEDIATE VICINITY OF OPERATIONS. 6.11 . COMPONENTS NOT CONSTRUCTED ACCORDING TO THESE SPECIFICATIONS SHALL BE REl.!OVEO AND REPlACED CONTRACTOR SHALL PROVIDE APPROPRIATE SAFETY MEASURES TO PROTECT THE PUBUC. PROPERLY AT THE EXPENSE OF THE CONTRACTOR. 1.7. ALL NEW STRUCTURAL WORK INCLUDING CONCRffi AND REINFORCEMENT SHALL BE ACCURATELY FIELD MEASURED 6.12. THE FACES OF THE FINISHED STRUCTURES SHALL BE TRUE. STRAIGHT. AND OF UNIFORM WIDTH, FREE FROM HUMPS, AND DIMENSIONS VERIFIED BY THE CONTRACTOR PRIOR TO ORDERING MATERIALS. CONTRJ.CTOR SHALL BE PREPARED SAGS, OR OTHER IRREGUI.ARITIES EXCEPT >S SPECIFIED IN THE PLANS. THE CONTRACTOR SHALL REPLACE Am TO IIAJ(E FIELD ADJUSTMENTS TO J.CCURATil.Y FIT THE NEW WORK TO EXISTlNG COND!TIONS. DEFICIENT SEGMENTS. 1.8. NO CONSTRUCTION SHALL COMMENCE UtmL All REQUIRED PERMITS AND APPROVA!.S HAVE BEEN SECURED AND 6.13. CONCRffi FORMWORKERS AND FINISHERS: THE CONTRACTOR H1S BEEN ISSUED NOTICE TO PROCEED. THE CONTRACTOR SHAtL SUPPLY A SUFFICIENT NUMBER OF EXPERIENCED CONCRETE FORMWORKERS AND FINISHERS 1.9. AnEtmON IS DIRECTED TO THE FN:T THAT THESE PLANS IAAY HAVE BEEN CHANGED IN SIZE BY REPROOUCTION. IN ORDER TO COMPLETE THE WORK. A CONCRETE FOREMAN WHO HAS A lHOROUGH UNDERSTANDING OF THE THIS SHOULD BE CONSIDERED WHEN OBTAINING SCALED DATA. PIANS, SPECIFICATIONS, AND REFERENCED SPECIFICATIONS SHALL SUPE!MSE ALI. FORt.tWORKERS ANO FlNISHERS. NO AND GOVERNING REGLLATIONS.FDEP, USACE. AND BROWAAO COUNTY. CONTRACTOR SHALL ADHERE TO ALL 1.10. CONSTRUCTION WORK SH.ILL BE EXECUTED IN ACCORDANCE WITH ALL LOCAi.. STATE, ANO NATIONAL BUILDING CODES SUB-STANDARD WORKIMNSHIP WILL BE ACCEPTED. CONDITIONS OF THE PERMITS AND EXEMPTIONS. 6.14. CONCRETE TRANSPORTATION: CONCRETE DELMRED FROM A READY I.IIX PLANT SH.ILL BE TRANSPORTED IN ACCORDANCE TO FOOT SECTION 345-13. CONCRffi THAT IS NOT PIACED IN THE FORM WITHIN iHE SPECIFIED TIME LIMITS WILL BE REJECTED ANO 2. LAYOUT AND TESTING NOT INCLUDED IN lHE WORK. CONTRACTOR SHALL BEAR All. COSTS FOR REJECTED CONCRETE. CONCRETE SHALL NOT BE PLACED IN THE FORMS UNTIL 1HE REINFORCING STffi PLACOIENT H1S Billi APPROVEO BY THE 2.1 . AU. CONSTRUCTION STAKEOUT SHAU. BE PERfORMED BY ANO PAID FOR BY lHE CONTRACTOR UNDER THE ENGINEER. SUPERVISION Of A SURVEYOR REGIST£RED IN THE STATE Of FLORIIY,. ALL TESTING ANO INSPECTION FOR CONCRETE 6.15. RElNFORCED CONCRffi MATERIALS TESTlNG: MATERIALS SHALL BE IN ACC0RDANC£ WITH FOOT SPECIFICATIONS AND SHALl BE PERFORMED B'I' NI INDEPENDENT THE CONTRACTOR SH.ILL HAVE AN INDEPENDENT TESTING l/lOORATORY TEST THE CONCRETE USED IN THE WORK. TESTING LABORATORY. THE TEST SHALL INCWDE 7, 14. AND 2B 1-'Y COMPRESSIVE STRENGTH TESTS . THE RESULTS SHALL BE SUPPLIED TO TliE ENGINEER. THE TESTS SHAU. BE IN ~ WITH ASTM CJ!. C39, AND C617. 3. DEMOLITION 6.16. ADHESIVE BONDED DOWELS SHALL BE INSTAU.ED IN ACCORDANCE WITH FOOT SECTION 416. J.1. CONTRICTOR SHALL VERIFY THE EXITNTS, LOCATION ANO OUANTITIES OF EXISTING ELEMENTS TO BE REMOVED. 7. STEEL 3.2. AU. DEBRIS WITHIN THE UNITS OF THE PROJECT SHALL BE HNJLEO OFF SITE BY THE CONTRACTOR. AS DIRECTED BY 1HE OY/NfR, AND DISPOSED Of AT AN APPROPRIATE F.-c1U1Y. 7.1. ALL REINFORCING STEEL SHALL CONFORM TO >STM A6t5, GRADE 60, DEFORMED BARS FREE FROM LOOSE RUST 3.3. CQNTR.ICTOR SHALL NOT OAINAGE ANY STRUCTURAL COMPONENTS BEYOND THE DEMOUTION REQUIREMENTS DEPICTED AND SCALE. IN THESE DRAWINGS. ANY DAMAGE Slw.l. BE REPNREO AT THE CONTAACTOR"S EXPENSE. 7.2 RONfORCINC STEEL. SUPPORTS, ANO TIE WIRE SHALL BE HOT-DIPPED GALVANIZED IN ACCORDANCE WITH >STM A767. 7.3. MMFX OR CHROMX 4100 STEEi. CAN BE USED >S AN ALTERNATE TO HOT-DIPPED GALVANIZED STEEL AT 4. STEEL SHEET PILING CONTF.ICTORS OPTION. 7.4. STEEi. SHALL BE PLACED AS SHOWN IN THE PLANS. AU. J.CCESSORIES SH.Ill. BE PLASl1C ONLY TO SUPPORT 4.1. STEEL SHEET PIUNG SH.11.L BE OF THE SECTIONS INDICATED, ANO SHIU BE >STM 1572 GRADE 50 OR HIGHER. REINFORCING EXPOSED TO WEATHER. ALI. REINFORCING STEEi. SHALL BE ACCURATELY LOCATED AND FIRMLY HELD IN 4.2. SHEET PILING SHAl.l BE COATED WITH TNEIIE TAR (46H-413) CON.. TNl EPOXY; TOP 15' WET FJ.CE. PlACE BEFORE ANO DURING lHE P!J.CE Of CONCRETE. 4.J. COATING SHALl BE 16 MILS DRY FllM THICKNESS, ANO APPi.JED IN STRICT ACCOROANCE WITH 11.ANUFN:TURER INSTRUCTIONS. 8. TIDAL DATA 4.4. SHEET PILING SHAU. BE INSTALLED WITH VIBRATORY HAMMER. 4.5. CONTRACTOR TO DRIVE SHEET PILING IN ACCORDANCE WITH FOOT 455-9. 8.1. CONTRACTOR MAY NEED TO ADJUST HIS WORK PLAN TO ACCOUNT FOR ACTUAL WATER LEVELS AND CHANGING 4.6. CONTRACTOR SHALL BE PREPARED TO DRIVE SHEET PILING THROUGH LIMESTONE LAYERS . WATER LEVELS. THE SITE MAY BE SUBJECT TO VARIABLE WAVE ANO SURGE CONOITlONS ANO IT IS THE 4.7. ANY OOIAGID COATING DUE TO HANDLING, DRMNG, ETC, SHALL BE REPAIRED IN STRICT ACCORDANCE WITH RESPONSIBILITY OF THE CONTRACTOR TO PROVIDE TEMPORARY SUPPORT FOR MARINE STRUCTURES AND SHORELINE COATING ~UFAClURER INSTRUCTIONS. DURING CONSTRUCTION. TIDAL DATA OBTAINED FROM SOUTH OELRAY BEJ.CH, FLORIDA STATION ID 8722781 . 4.8. ALL PllfS SHALL BE DRIVEN TO THE MINIMUl,I TIP ELEVATIONS INDICATED UNLESS OTHERWISE APPROVED BY ENGINEER. 9. SUBMITIALS 4.9. EXTEND EXISTING DRANAGE PIPES lHROUGH STEEL SHEET PILE AT SAME ELEVATION WITH REINFORCED CONCRETE OUTFALL COLLAR, AS APPLICABLE. f 9.1 . REVIEW OF SUBMITTA!.S BY THE STRUCTURAL ENGINEER IS FOR GENERAL CONFORMANCE WITH THE DESIGN CONCEPT AS PRESENTED BY THE CONTRACT DOCUMENTS. NO DETAILED CHECK OF QUANTITIES OR DIMENSIONS WILL BE MADE. 5. REINFORCED CONCRETE PILING 9.2. AU. SHOP DRAWINGS MUST BEAR EVIDENCE OF THE CONTRACTOR'S APPROVAL PRIOR TO SUBMITTING TO EOR. 9.3. THE FOLLOWING t.llNll.tUM SUBMITTALS SHALL BE PREPARED B'I' THE CONTRACTOR AND SUBMITTED TO THE ENGINEER ! ~ I 5.1. CONCRETE TO BE MINIMUM 6.000 PSI, AND FOUOW FOOT ClASS-V CONCRffi SPECIFICATIONS. MINll.tUt.t CONCRETE FOR REVIEW AND APPROVAL PRIOR TO RELATED CONSTRUCTION ACTMTY: COVER TO INTIRNAL REINFORCENOO SHALL BE 3" ON AU. SIDES. 9.J.1. SCHEDUL£ FOR COMPLETION OF WORK WITH TASKS AND DURATIONS DEFINED 5.2. PILES SHALL BE DRIVEN A MINIMUM OF 12 FEET INTO FIRM MATERIAL AND PROVIDE A MINIMUM BEARING CAPACITY 9.3.2. CONCRETE MIX OF 35 TONS/PILE. PILE LOGS SHALL BE RECORDED FOR ALL DRMN PILES. l 9.3.3. REINFORCING 5.3. PllfS SHALL BE CUT OFF AT ELEVATIONS SHOWN IN THE PLANS AND SECTIONS HEREIN. 9.J.4. STEEL SHEET PII.E 5.4. CQNTR.ICTOR TO SUBMIT SHOP DRAWINGS FOR CONCREJE PILES. 9.3.5. UTILITY CONDUIT PENETRATION FOAM 5.5. PILES SH.11.1. BE fROM A FOOT CERTIFlED FACIUlY Of PRESTRESSED CONCRffi PRODUCTS. <;" 9.3.6. FINGER PIER STEPS & FRAMING 5.6. INDICATOR Pn..E LOG(S) SHAU. BE SUBMITTED TO ENGINEER Of RECORD FOR CONFIRMATION IF PRODUCTION PILE ii LENGTH. t 10. DESIGN CRITERIA 5.7. INDICATOR PILE TO BE +10 Fm MIN LONGER THAN PRODUCTION PILES. l BULKHEAD SURCHARGE LL• t 00 PSF VESSEL LENGTH, LOA= {0 FT f 6. CONCRETE DESIGN IN ACCORDANCE WITH 2017 FBC. ~ 318-14, ASCE 7-10, FOOT STANOAAD SPECIFICATIONS FOR ROAD & BRIDGE CONSTRUCTION -" 6.1. FORMS FOR THIS WORK SHALL BE ~ OF EITHER WOOD OR METAL THEY SHAU. BE STRAIGHT AND FREE OF '#NIP OR BENDS. THEY SHAU. HAVE SUFFICIENT STRENGlH »Ill RICIOtTY, WHEN STAl<fD, TO RESIST lH£ PRESSURE 11. CONSTRUCTION METHODOLOGY OF THE CONCRETE WITHOUT SPRINGING. If WOOOEN FORMS Nlf. USED, THEY SHALL BE Of AIJEQUATE SECTION AND 1 i ~ SHALL HAVE A FLAT SURfJ.CE ON TOP. FORMS SIW.l. HAVE A DEPTH AT LEAST EQUAi. TO THE V£RTICII. ~~~E~~~ :tvC:::~ ~~UN~=·~= riOR~~\~~m ll.t. ~IO~t~l~~t~ ~4~~~ ~-1~~~~ ~:N~~All~~E ! THE CONCRETE HAS SET. INSTALLED FOLLOWING THE !ONG PILE TO BE REMOVED TO PROVIDE TEMPORARY SHORING TO RESIST PANEL SYMBOLS LEGEND PROJECT CORONADO CONDOMINIUM BULKHEAD REPLACEMENT a.JENT CORONADO AT HIGHLAND BEACH CONDOMINIUM ASSOCIATION ENGINEER CUMMINS CEDERBERG COASTAL & MARINE ENGINEERING 7550 RED ROAD, SUITE217 SOUTH MIAMI. FLORIDA 3314J TEL: •1305741..S155FAX: • 1305-S74-1969 WWW.CUMMINSCEDERBERG,COM COA#29002 DETAIL NUMBER=:@ SHEET WHERE DETAIL S-!.2 IS SHOWN DETAIL SYMBOL / DIRECTION Of VIEW FDR SECTION CUT ~ 8 ~ SHEET WHERE SECTION~ IS SHOWN VERTICAL DATUM 1-::,.""P,...:~c;...rNO-"-l. -=::"=-----1 Station ID 8722761 = JT ~MHW LINE SCALE ASSHCMN SHEET TITLE 0.29' T NAV088 GENERAL NOTES SHEET 2 OF 8 -4-MLWUNE S-1.1 ~ L--.:::6.!c!.2._.:.::JIJST=..:PRtO.=R:_T:.:::cO..c.PlACIN=e::G_cTHE=..,CONC=::.:,RETE::.:...,Nff.:.:.:.....l'IOOOEN==..,.::FORM=S_,SHALL=,_,BE~MOISTENED==~AN~O~AU.=cSTEEl."-'..:=~REle!!.!N~FORCtNG=~----~COWPSE=..:..::'....:' PRl..:::::OR.:...T:.:0...::K::.:ING:....:..::PILE=--:.:R::EM::;OV:::AL.:..._ _________________________________ J!....=~~=~....,!!HTS~-------_J ABBREVIATIONS J.CI AMERICAN CONCRffi INSTllUTE >STM AMERICAN SOCIETY FOR TESllNG AND MATERIALS CONT CONTINUOUS CONTD CONTINUED f1lEP FLORIDA DEPARTMENT OF ENVIRONMENTAL PROTECTION FOOT FLORIDA DEPARTMENT OF TRANSPORTATION KSI ~ INC\l IOPS PER MHW MEAN HIGH WATER 111N MINIMUM MLW MEAN LOW WATER NAW NORTH AMERICAN VERTICAL DATUM NGVO NATIONAL CEOOETIC VERTICAL DATUM PERA PERMITTING, ENVIRONMENT, AND REGULATORY AFFAIRS PSI POUNDS PER SQUARE INCH TYP TYPICAL USACE UNITED STATES ARMY CORPS OF ENGINEERS W/C WAiER/CEMENT RATIO 4 . .3+ NOTES: 1. BOUNDARY SURVEY CONDUCTED BY EXACTA COMMERCIAL SURVEYORS , INC. DATED 09/09/2018. 2 . AERIAL IMAGE: LABINS 2015 . EXISTING CONDITIONS PLAN SCALE: 22x34: 1" = 15' 11 x 17: 1" = 30' PROJECT CORONADO CONDOMINIUM BULKHEAD REPLACEMENT CllENT CORONADO AT HIGHLAND BEACH CONDOMINIUM ASSOCIATION ENGINEER CUMMINS CEDERBERG COASTAL & MARINE ENGINEERING 7550 RB) ROAD, SUITE 21 7 / ·S•I / '· //_,-EXIST. PILE TO REI/AIN EXIST. CONC. PANEL TO REMAIN \ ' ' \ ' \... 14" SQ. CONC. KING PILE TO BE REMOVED AS NEEDED CROSS SECTION @ SCALE: 22x34 - 1"=2' S-1. 11x17 -1"=4' CC PROJECT NO. 46300 DRA'MI JOR EXISTING CONDITIONS S>1EET 3 OF 6 S-1 .2 PROJECT CORONADO CONDOMINIUM BULKHEAD REPLACEMENT CUENl' CORONADO AT HIGHLAND BEACH CONDOMINIUM ASSOCIATION ENG•"5R CUMMINS CEDERBERG COASTAL& MARINE ENGINEERING 75SORED ROAO, SU!TE 217 SOUTH MlAM!, FLORIDA 3314:3 TEL.;•1305741-6155 FAX: •tJOS.874.1B69 WWW.CUMMfllSCEDERBERG.COM COA#20062 ,,111111,,,, 1#\Ylo~'',,. "'* . ca, ••••••••• 'T ~~ . •.ise ··· .. .,..., ~~ ~ • ? ~ - O..• C, :11 ••• to:~ o...a'f. •• V • ·. ,(). ~·· ,,r,;; . CC PROJECT NO. .:6300 DRAWN JOR CHECKED Jr 1.:. I tc: '~- 111 (~ I ,,k I I .. ,\· ~1Jj.1!5i2Bllll~~""'11.,;;,m\,!!Jl!lltl.!l..-----J ~•N~ """''" am ,o ll:J;)1, ~ --,,c, -- ~-,11~, ~ II.lo!', 11:.u ~. x---e-------o ,! t\lll 'l'I•! ,~. CORONADO AT HIGHLAND BEACH CONDOMINUM RENOVATIONS 3400 SOUTH OCEAN BO ULEVARD, HIGHLAND BEACH, FLOR IDA CORANADO AT HIGHLAND BEACH, CO NDOMINUM ASSOCIATION SEPTEMf!IER 2011 P ct Namo : 33S5 Coronado HI hlan d Belch Condominium ProactNumbor:25:3315 \ "'''' ~ ~ -~: -= - ~ ""): . . •?\ : --· ~ -. , ~ ,,. SOIL BORINGS SHEET 4 OF 6 NOTE: SOIL BORINGS PROVIDED BY ECS SHOWN HERE FOR REFERENCE ONLY. S-1.3 + 4.3+ NOTES: 1. BOUNDARY SURVEY CONDUCTED BY EXACTA COMMERCIAL SURVEYORS , INC. DATED 0 9/09/2018. DEMOLITION PLAN LEGEND TIUB ER DDCK (TO BE PAR TW.LY RE\.\\Yi£0 fOR CONSTRUCTION) rEXIST. PILE TO RDIAIN /// / m!BER DOCK (DE\.IOL\SH DECK 1£ JOISTS TO THE FI RST PILE) _,,-EXIST. CONC. PANEL ,/ TO REMAIN \_14" SQ. CONC . KING PILE TO BE REMOVED >S NEEDED CROSS SECTION @ PROJECT CORONADO CONDOMINIUM BULKHEAD REPLACEMENT CllENT CORONADO AT HIGHLAND BEACH CONDOMINIUM ASSOCIATION 3400Sou!h0eean8otkvanf -Beoch,Fl33467 .-, N -~ !!l CX:: PROJECT NO. DEMOLITION PLAN ~ 2 . AERIAL IMAGE: LABINS 2015. :;; SCALE: 22 x34: 1" = 15' ~ TO BE DEMOLISHED SCALE: 22 x3 4-1"=2' S-2.0 S-2.0 11x17: 1" =30' 11 x17-1"=4' t l___ _____________________________________________ __._ ___ ___, I 443' LEGEND : PILE SUMMARY EJ: EXPANSION JOINT 1------,-------- CJ : CONTROLJOINT PILE iYPE # OF PILES 14"X 14" 44 NOTE: PROPOSED PLAN VIEW 443 LINEAR FEET OF SEAWALL TO BE SCALE: 22x34: 1" -10' INSTALLED (SHEET PILES , CONCRETE 11 x 17: 1" =20' BA TIER PILES AND CONCRETE CAP) PROJECT CORONADO CONDOMINIUM BULKHEAD REPLACEMENT CLIENT CORONADO AT HIGHLAND BEACH CONDOMINIUM ASSOCIATION ENGINEER CUM MINS CEDERBERG COASTAL!, MAR INE ENGINEERING 7550 RED ROAD, SUITE 217 SOUTH ML&.M1, FLORIDA 331.C TEL:•1305 74'k5155 FAX:+1 305-874-1969 WWW.CUl.1MNSCEDER8ERG.COM CC PROJECT NO, PROPOSED PLAN VIEW SHEET 80F 8 ~ ; S-3.0 ~l L_ ___________________ _____________ ......___ __ ~ ~------~~-----------~ I PROPOSED SJO>S I CONCRETE C>P (APPROX 1 o· o c. MAX) I L--------------------~ BUL[c~L~~~i~.~1!AL PLAN@ 11x17: 1" = 6' PROPOSED CONC. C>P LB TOP OF C>P ~ ~ EL +5.5' NAVO MUDUNE (ELEV. VAR IES) 3'-o· PROPOS ED NZ-14. ~ ~ PROJECT CORONADO CONDOMINIUM BULKHEAD REPLACEMENT Ctl€NT CORONADO AT HIGHLAND BEACH CONDOMINIUM ASSOCIATION 3,;(X)South0cean~rd H~d8eac:h.FL33487 ENGINEER CUMMINS CEDERBERG COASTAL& MARINE ENGINEERlt-.'G 7550 RED ROAD, SU!TE217 SOUTH MIAMI, FLORIDA 3'.3143 TEL: +1305741-6155 FA.X : +1305~74-1969 WWW.CUMMIN6CEDER6ERG.C0M COA#29r62 -f~"w-'Tl"'-P.'--'E=L_--=22"-"'-"VO-"---TS .0-'-N"- PROPOSED BULKHEAD SECTION A SCALE: 22x34-1"=2' -3. 11x17-1"=4' END TERMINATION~ END TERMINATION Lu ~ DETAIL ~ DETAIL ~ I I 1 SCALE: 22x34: 1" = 2' SCALE: 22x34: 1" = 2' 11x17 : 1" =4' 11x17: 1"=4' I I I ' l TOP OF DOCK I I I EL +4.0' MIN. I NAVO SIMPSON LTS12 CONC. C>P OPP. SIDE l PROPOSED STEP SECTION I SCALE: 22x34-1"=2' 11 x17-1 "=4' 1 I "-' CC PROJECT NO. 463:Y.l :/i ORA\<\t.l JOO CHECKS) DRU 14" & EPOXY PROPOSED NZ-ly-;-\ I SHEETPllf ~I I I I I I I I I j" CHAMFER TYP. ON EXPOSED EDGES $ ELEV . +5.5' NAVO PRO\IIDE #4 STIRRUPS O 12· o.c. f ~~~~H~~lf SECTIONS PIER /CAP CONNECTION ~ DETAIL ~ f PROPOSED BULKHE~~~~~~~~~EMENT DETAIL@ SHEET 7 OF• } 11x17-1"=4' N.T.S. S-3.1 f t t__ ____________________________________________________________________________ _,__ ______ __ i• CHAMFER All AROUND W/ ELASTOMERIC SEALANT 1 • E.J. 'II/ EIASTOMERIC \ SEAIANT ALL AROUND \ JNT. ia-=;t=;;;:;.,-4-..=:iu M--4----1----lal "-, t~':FtR ALL ~ \ ct HOOK TOP BARS O JNT. (3" CLR.) ~~~f~~f:o-· CAP ASPHALT/C FIBERBOARD __,,,/"' DO UBLE STIRRUPS EACH REJNF. CONT. BATTER PILE SIDE OF JOINT '·,,-.... SLEEVE DOWEL ONE CONCRETE CAP SIDE OF JOINT, lYP. CONTROL JOINT DETAIL @ EXPANSION JOINT DETAIL~ ~ ,-REINFORCED / CONCRETE CAP ELEV. +5.5' NAVO ~ rHSS s·,s·~ UTILITY SLEEVE CONDUIT. CONDUIT SLEEVES TD BE FILLED WITH SEAWALL PENETRATIONl SEALER/URETHANE FOAM · NZ NZ HOT-ROLLED STEEL SHEET PILE ~ ~ I UTILl~L~:~~~~ 1.~ 3 1 2 s iral Tie 1" Spacing 11x17-1"=4' J4 • SO. PU f SPFCIFICATION· 1. F c' = 6,000 PSI (MIN) 2. (8) o.s· DIA. GRADE 270 LRS 3. ~IIN. 3" COVER ON ALL REINF. 14" SQ. PRESTRESSED CONCRETE/s\ DETAILS 4. ALL PILINGS TO FOOT CONCR. CLASS V SPEC. 5. PILING TO ACHIEVE BEARING CAPACJTY Of 35 TONS PILE DETAIL ~ 6. CONTRACTOR TD MAINTAIN PILE LOGS. SHEETaOF8 N.T.S. SECTION A-A S-3.2 REINFORCED l '.:_, ':Ci . ·-_ _ _ -· __ ¥. MHW = +0.29' NAVO -•• 1=-' _ ,-..r / I J I I CONC. 14" BAm:R PILE TOP VIEW SECTION A CONC . 14" BATTER PILE ?ETAIL @ PROJS:::T CORONADO CONDOMINIUM BULKHEAD REPLACEMENT CLIENT CORONADO AT HIGHLAND BEACH CONDOMINIUM ASSOCIATION J400South0Ge11nBotje,,,-ard Hijjlt-«!n<SBeec:h.F'\..33487 ENGINEER CUMMINS CEDERBERG COASTAL& MARINE ENGINEERING 7550 RED ROAD, SUITE 217 SOUTH MIAM I, FLORIDA 3314:3 TEL:•1305741-6155 FAX:•1305-874-1959 WWW,CUMMINSCEOERBERG.COM COA#29062 CC PROJ!:CT NO. CHECKED JT 15 Turns 3• Pitch 14" e· Ptch A----1 A_j 16 Turns 3" Pitch 1" Town of Highland Beach Town Commission Development Order Application No. 19-0370 Applicant: Coronado Highland Beach Condos Property Address: 3400 S. Ocean Blvd Highland Beach, Florida 33487 CERTIFICATE OF MAILING I hereby certify that the Town Clerk's Office mailed a copy of the Notice of Public Hearing (Exhibit A) for Application No. 19-0370 for the property located at 3400 S Ocean Blvd, Florida 33487, by U.S. certified registered mail with return receipt requested and U.S. regular mail to: All property owners and to properties owned by, a condominium association president and the association's registered agent within 1,000 feet of the property located at 3400 S. Ocean Blvd, Highland Beach, Florida 33487. The mailings consisted of 830 notices sent certified registered mail and returned receipt requested and 61 notices sent priority mail. This 21'day of June 2019. Highland Beach Town Clerk's Office Beverly Wri t Deputy Town Clerk ���y TOWN OF HIGHLAND BEACH ,1=-- - NOTICE OF PUBLIC HEARING \ 'czoR10P TOWN COMMISSION YOU ARE HEREBY NOTIFIED that the Town Commission of the Town of Highland Beach will conduct a Public Hearing on Tuesday, July 2, 2019 at 1:30 PM in the Commission Chambers at Town Hall, 3614 South Ocean Boulevard, Highland Beach, Florida to consider the following application: REQUEST SUBMITTED BY CORONADO AT HIGHLAND BEACH CONDO ASSOCIATION, INC. LOCATION: 3400 S. OCEAN BLVD, HIGLAND BEACH, FLORIDA 33487. APPLICATION #19-0370 — APPLICANT IS PROPOSING TO REPLACE/REPAIR A FAILING SEAWALL ALONG THE INTRACOASTAL WATERWAY. THE SEAWALL IN PLACE HAS REACHED/EXCEEDED ITS EXPECTED SERVICE LIFE AND IN THE OPINION OF CUMMINS CEDERBERG INC., IS IN "SERIOUS" CONDITION OVERALL. THE APPLICANT IS PROPOSING TO INSTALL APPROXIMATELY 443 FEET OF STEEL SHEET PILES, 42 PRESTRESSED CONCRETE BATTER PILES, NEW CAST IN PLACE CONCRETE SEAWALL CAP,AND PARTIAL REMOVAL/REPAIR OF 9 WOOD FINGER DOCKS. The application is available for inspection in the Town Clerk's Office at Town Hall, Monday through Friday during normal business hours of 8:30 a.m. to 4:30 p.m. Any person that decides to appeal any decision made by the Town Commission with respect to any matter considered at this meeting, such person will need to ensure that a verbatim record of the proceeding is made,which includes the testimony and evidence upon which the appeal is based. The Town of Highland Beach does not provide such a record. In accordance with the Americans with Disabilities Act,persons who need special accommodation to attend or participate in this meeting should contact the Town Clerk's Office at (561) 278-4548 at least 48 hours prior to the meeting. If you are hearing or speech impaired, please contact the Florida Relay Service at 1-800-955-8770 or 1-800-955-8771. For additional information, please contact the Building Department at 561-278-4540. TOWN OF HIGHLAND BEACH BUILDING DEPARTMENT NOTE: Per the Town of Highland Beach Code of Ordinance,Section 6-128(a),written notice of the above-mentioned Public Hearing is mailed via U.S.certified mail with a return receipt requested and U.S.regular mail to all property owners abutting the proposed wall within one thousand(1,000)feet on the ocean or on the waterway. If an affected property is subject to,or owned by,a condominium association,written notice may be provided only to the association president and the association's registered agent,who shall be responsible for disseminating this notice. SUN -SENTINEL SUN -SENTINEL Published Daily Fort Lauderdale, Broward County, Florida Boca Raton, Palm Beach County, Florida Miami, Miami -Dade County, Florida State Of Florida County Of Broward Before the undersigned authority personally appeared MARK KUZNITZ, who on oath says that he or she is a duly authorized representative of the SUN- SENTINEL, a DAILY newspaper published in BROWARD/PALM BEACH/MIAMI-DADE County, Florida; that the attached copy of advertisement, being a Legal Notice in: The matter of 11720 -Notice of Public Meeting, Town of Highland Beach Florida Tuesday July 2nd Public Meeting Proposed Ordinance Was published in said newspaper in the issues of, Jun 22, 2019 Affiant further says that the said SUN -SENTINEL is a newspaper published in said BROWARD/PALM BEACH/MIAMI-DADE County, Florida, and that the said newspaper has heretofore been continuously published in said BROWARD/PALM BEACH/MIAMI-DADE County, Florida, each day and has been entered as second class matter at the post office in BROWARD County, Florida, for a period of one year next preceding the first publication of the attached copy of advertisement; and affiant further says that he or she has neither paid nor promised, any person, firm or corporation, any iscount, rebate, commission or refund, for the purpose of securing this ad is e t for p"before newspaper. Signature o Affiant Sworn to and ,gibscri: June 24, 2019. ASHLEY MESSERSCHMIDT of Notary Public Notary Public -State of Florida =* *= Commission # GG 168665 ,;rF oP My Commission Expires May 17, 2020 Name of Notary, Typed, Pri e ampe Personally Known (X) or Produced Identification ( ) Sold To: Town of Highland Beach Florida - CU00661788 3614 S Ocean Blvd Boca Raton,FL 33487-3393 Bill To: Town of Highland Beach Florida - CU00661788 3614 S Ocean Blvd Boca Raton,FL 33487-3393 Affidavit Delivery Method: U.S. Mail Affidavit Email Address: 6329632 RECEIVED JUN 8 `'019 Fawn of t4icE3,each, F!. wvvry ur HIGHLAND BEACH, FLORIDA NOTICE OF PUBLIC NOTICE ' TOWN COMMISSION YOU ARE HEREBY NOTIFIED that the Town Commission of the Town of Highland Beach will conduct a public hearing on Tuesday, July 2, 2019 at 1:30 PM in the Commission Chambers at Town Hall, 3614 South Ocean Boulevard, Highland Beach, Florida, to consider the following application. REQUEST SUBMITTED BY CORONADO AT HIGHLAND BEACH CONDO ASSOCIATION, INC. LOCATION: 3400 S. OCEAN BLVD, HIGLAND BEACH, FLORIDA 33487. APPLICATION #19-0370 -APPLICANT IS PROPOSING TO REPLACE/REPAIR A FAIL- ING SEAWALL ALONG THE INTRACOASTAL WATERWAY. THE SEAWALL IN PLACE HAS REACHED/EXCEEDED ITS EXPECTED SER- VICE LIFE AND IN THE OPINION OF CUM- MINS CEDERBERG INC., IS IN "SERIOUS" CONDITION OVERALL. THE APPLICANT IS PROPOSING TO INSTALL APPROXIMATELY 443 FEET OF STEEL SHEET PILES, 42 PRESTRESSED CONCRETE BATTER PILES, NEW CAST IN PLACE CONCRETE SEAWALL CAP, AND PARTIAL REMOVAUREPAIR OF 9 WOOD FINGER DOCKS. A copy of the proposed ordinance is available for public inspection in the Town Clerk's Office at Town Hall, 3614 So. Ocean Boulevard, Highland Beach, Florida 33487. All interested persons are encour- aged to attend the Public Hearing and be heard with respect to the proposed ordinances. Any person that decides to appeal any decision made by the Town Commission with respect to any matter considered at this meeting, such person will need to ensure that a verbatim record of the proceeding is made, which includes the testimony and evidence upon which the appeal is based. The Town of Highland Beach does not provide such a record. In accordance with the Americans with Disabilities Act, any individual with a disability requesting reasonable accom- modation in order to participate in this meeting should contact the Town Clerk's Office at 561-278-4548 at least 48 hours prior to the meeting. If you are hearing or speech impaired, please contact the Florida Relay Service at 1-800-955-8770 or 1-800-955-8771. Lanelda Gaskins, MMC Town Cler< Published: Sun sentinel Saturday,lgne 22, 2019 ')6/22/20P